ARRIVING SOON! AIRTAC AT200 Regulator with Super-Flex HPA Adapter Kit
This is the setup used to test all our HPA adapters. The AT200 regulator provides a high refresh rate, tournament lock, wide pressure range, and is backed by a lifetime warranty. The 40-inch super-flex line features a large bore for increased volume, ensuring stable full-auto firing and sustained bursts, while remaining exceptionally flexible. Completing the bundle is our Tier 1 Precision 0.8L tank. All tanks are shipped empty, as standard for pressure equipment.
Ensure your airsoft game is smooth, reliable, and always at peak performance with this trusted setup. Feel the confidence of unmatched precision and durability in every match
Safety Information:
Applicable to Any Airsoft Regulator Used with Any HPA Tank
When connecting a secondary regulator (e.g., Wolverine Storm Cat5, Airtac AT200, Balystik HPR800C) to an HPA tank, avoid overtightening. Attach the regulator when the tank is full, and tighten until it pressurizes or stops rotating freely—no excessive force is needed for a proper seal.
If the secondary regulator 'binds' due to over-torquing or debris, have the tank emptied by a professional or use a tank emptying tool. Grip the primary regulator's wrench flats and carefully unscrew the secondary regulator to prevent damage or accidental unscrewing of the primary regulator.
All tanks are shipped empty as standard. They may be from brands such as Dye, Combat Games Essentials, or HK Army, with the same capacity and function.
Filling the Cylinder:
Only trained personnel should fill this cylinder, adhering strictly to the marked capacity. Improper filling can cause serious injury or damage.
Using the Cylinder:
Designed for airsoft/paintball use only. Keep out of reach of children. Do not remove or cover labels. Store in a cool, dry, ventilated area. Do not expose to heat above 250°F/121°C or corrosive substances. Never modify or tamper with the cylinder.
Safety & Maintenance:
Retest every 5 years by a qualified professional. Keep the thread and interior free from oil and dirt. Inspect regularly for signs of damage—dents, corrosion, or leaks— and condemn if found. Never attempt unauthorized repairs, modifications, or use beyond the cylinder’s intended purpose.
Never:
- Modify or alter the cylinder.
- Drop, heat, or expose it to excessive temperatures.
- Force or tamper with valves or threads.
- Fill with gases other than specified.
- Use if damaged, leaking, or past the retest date.
- Fill beyond the rated capacity.
Always handle high-pressure cylinders with caution and respect to ensure safety.
This is the setup used to test all our HPA adapters. The AT200 regulator provides a high refresh rate, tournament lock, wide pressure range, and is backed by a lifetime warranty. The 40-inch super-flex line features a large bore for increased volume, ensuring stable full-auto firing and sustained bursts, while remaining exceptionally flexible. Completing the bundle is our Tier 1 Precision 0.8L tank. All tanks are shipped empty, as standard for pressure equipment.
Ensure your airsoft game is smooth, reliable, and always at peak performance with this trusted setup. Feel the confidence of unmatched precision and durability in every match
Safety Information:
Applicable to Any Airsoft Regulator Used with Any HPA Tank
When connecting a secondary regulator (e.g., Wolverine Storm Cat5, Airtac AT200, Balystik HPR800C) to an HPA tank, avoid overtightening. Attach the regulator when the tank is full, and tighten until it pressurizes or stops rotating freely—no excessive force is needed for a proper seal.
If the secondary regulator 'binds' due to over-torquing or debris, have the tank emptied by a professional or use a tank emptying tool. Grip the primary regulator's wrench flats and carefully unscrew the secondary regulator to prevent damage or accidental unscrewing of the primary regulator.
All tanks are shipped empty as standard. They may be from brands such as Dye, Combat Games Essentials, or HK Army, with the same capacity and function.
Filling the Cylinder:
Only trained personnel should fill this cylinder, adhering strictly to the marked capacity. Improper filling can cause serious injury or damage.
Using the Cylinder:
Designed for airsoft/paintball use only. Keep out of reach of children. Do not remove or cover labels. Store in a cool, dry, ventilated area. Do not expose to heat above 250°F/121°C or corrosive substances. Never modify or tamper with the cylinder.
Safety & Maintenance:
Retest every 5 years by a qualified professional. Keep the thread and interior free from oil and dirt. Inspect regularly for signs of damage—dents, corrosion, or leaks— and condemn if found. Never attempt unauthorized repairs, modifications, or use beyond the cylinder’s intended purpose.
Never:
- Modify or alter the cylinder.
- Drop, heat, or expose it to excessive temperatures.
- Force or tamper with valves or threads.
- Fill with gases other than specified.
- Use if damaged, leaking, or past the retest date.
- Fill beyond the rated capacity.
Always handle high-pressure cylinders with caution and respect to ensure safety.